General Specifications |
|
Cable Type |
Cordage |
|
Construction Type |
Non-armored |
|
Subunit Type |
Gel-free |
|
|
|
Construction Materials |
|
Fiber Type Solution |
LazrSPEED® 550, 50 μm multimode fiber |
|
Total Fiber Quantity |
1 |
|
Fiber Type |
LazrSPEED® 550, 50 μm multimode fiber |
|
Fiber Type, quantity |
1 |
|
Jacket Color |
Aqua |
|
|
|
Dimensions |
|
Cable Weight |
0.7 lb/kft | 1.0 kg/km |
|
Diameter Over Jacket |
0.90 mm | 0.04 in |
|
|
|
Physical Specifications |
|
Minimum Bend Radius, loaded |
5.0 cm | 2.0 in |
|
Minimum Bend Radius, unloaded |
3.0 cm | 1.2 in |
|
Tensile Load, long term, maximum |
20 N | 4 lbf |
|
Tensile Load, short term, maximum |
15 lbf | 67 N |
|
Vertical Rise, maximum |
500.0 m | 1640.4 ft |
|
|
|
Flame Test Specifications |
|
Flame Test Listing |
NEC OFNR-LS (ETL) and c(ETL) |
|
Flame Test Method |
IEC 60332-3 | IEC 60754-2 | IEC 61034-2 | IEEE 383 | UL-1666 | UL-1685 |
|
|
|
Environmental Specifications |
|
Environmental Space |
Low Smoke Zero Halogen (LSZH) |
|
Installation Temperature |
-30 °C to +70 °C (-22 °F to +158 °F) |
|
Operating Temperature |
-20 °C to +70 °C (-4 °F to +158 °F) |
|
Storage Temperature |
-40 °C to +70 °C (-40 °F to +158 °F) |
|
|
|
Mechanical Test Specifications |
|
Compression |
10 N/mm | 57 lb/in |
|
Compression Test Method |
FOTP-41 | IEC 60794-1-2, Section 7 |
|
Flex |
300 cycles |
|
Flex Test Method |
IEC 60794-1-2, Section 10 | FOTP-104 |
|
Impact |
0.55 ft lb | 0.74 N-m |
|
Impact Test Method |
FOTP-25 | IEC 60794-1-2, Section 8 |
|
Strain |
See long term and short term tensile loads |
|
Strain Test Method |
FOTP-33 | IEC 60794-1-2, Section 5 |
|
Twist |
10 cycles |
|
Twist Test Method |
FOTP-85 | IEC 60794-1-2, Section 11 |
|
|
|
Environmental Test Specifications |
|
Heat Age |
-20 °C to +85 °C (-4 °F to +185 °F) |
|
Heat Age Test Method |
Not applicable |
|
Low High Bend |
-20 °C to +70 °C (-4 °F to +158 °F) |
|
Low High Bend Test Method |
FOTP-28 | IEC 60794-1-2, Section 28 |
|
Temperature Cycle |
-20 °C to +70 °C (-4 °F to +158 °F) |
|
Temperature Cycle Test Method |
FOTP-3 | IEC 60794-1-2, Section 22 |
|
|
|
Qualification Specifications |
|
Cable Qualification Standards |
ANSI/ICEA S-83-596-2001 | Telcordia GR-409-CORE Issue 2 |